Emergency and roadside DEF, DPF, EGR and derate diagnostics

DEF warning, DPF light or truck in derate?

Nexgen diagnoses aftertreatment and derate problems on commercial trucks: DEF level, quality and heater faults, DPF soot loading and regenerations that will not finish, EGR faults, and trucks that have limited their speed or power. Many of these faults can be read and narrowed down where the truck stands, and some sensor, heater and wiring repairs can be done there. We will not delete, bypass or tamper with any emissions system. If the truck has derated, get to a safe place to stop while it still has power, note the warnings and call.

Can I drive during a DEF or DPF derate?

For a short distance, sometimes, but plan to stop. Most trucks escalate in stages: a lamp, then a cut in torque, and if the fault stays a much harder speed limit that can leave a loaded truck far below highway traffic speed. Leaving the highway for a safe stop while the truck still pulls is usually safer than crawling along the shoulder lane. Continuing to operate with a DPF that keeps failing to regenerate, or an EGR fault with rising engine temperature, may risk further damage to the filter or the engine.

Aftertreatment: DPF load and DEF dosing Example

Example: exhaust heat through the stack during a regeneration; a filter that cannot complete one, or a DEF fault, is what brings on a derate.

Call the nearest location.

Call now (204) 960-5390

Injury, fire or danger: call 911 first. We take calls 24/7.

Problems we commonly inspect

DEF warning or derate countdown
A low-DEF, DEF quality or SCR lamp, often with a message that power or speed will be limited after a set distance or on the next restart.
DEF faults in the cold
Heater or DEF temperature faults on frosty mornings, or a warning that only appears after the truck has sat outside.
DPF lamp on, or regen needed again and again
Soot load climbing faster than normal, regenerations requested every few days, or a parked regen that will not start.
Regeneration stops before it finishes
The regen begins, then quits; the soot level hardly drops and the lamp comes back.
High exhaust temperature lamp
Normal during an active regen, but worth a call when it stays on with smoke, a burning smell or loss of power.
EGR fault and loss of power
An EGR lamp or code with sluggish pulling, black smoke, or engine temperature creeping up.
Truck limited to a low speed
The final derate stage: the truck will not go above a crawl, or refuses to rev, until the fault is found and cleared properly.

Stop driving, or can it wait?

Stop and get help

  • The truck has reached the final derate stage or is limited to a speed that is unsafe in traffic.
  • The high exhaust temperature lamp is on together with smoke, a burning smell or flames.
  • The DPF or check-engine lamp is flashing and power is dropping.
  • An EGR fault appears and the engine temperature gauge keeps rising.

May be safe to assess further

  • A low-DEF lamp only, the truck pulls normally and you have DEF of known quality to add.
  • A steady DPF lamp with normal power, where your truck and company procedure allow a parked regeneration in a safe place.
  • A single EGR or aftertreatment lamp with no change in power, temperature or smoke.

Continuing to operate may risk further damage or create a safety issue. When in doubt, stop where it is safe and call. Injury, fire or immediate danger: call 911 first.

What to do right now

  1. Note exactly which lamps are on, whether any are flashing, and any message, countdown or speed limit shown on the dash.
  2. If a derate is coming, plan a safe stop now: an exit, a wide shoulder or a yard, off the travelled lane with hazards on.
  3. If the DEF gauge reads low and you carry sealed DEF from a known source, topping up is a normal driver task. Put nothing else in the DEF tank.
  4. During a regen or with the high exhaust temperature lamp on, park away from dry grass, fuel, buildings and people.
  5. Call with the lamps, the messages and how the truck has been driving. Fire, injury or immediate danger: call 911 first.

What not to do

  • Do not delete, bypass, disable or tamper with the DEF, DPF or EGR systems. Nexgen will not do it either.
  • Do not add water, additives or DEF from an open or unknown container to the DEF tank.
  • Do not keep clearing codes to make a derate go away. The fault returns, and the cleared data can make the cause harder to find.
  • Do not touch the exhaust, DPF or SCR housing after a regen. They stay very hot well after the engine stops.
  • Do not park for a regen over dry grass, near fuel or beside a building.

When you call, have ready

  • Every lamp and dash message, and whether a countdown, a speed limit or a stop-engine warning is showing.
  • Engine make, model and year, and the truck unit number.
  • When DEF was last added, from a pump or a jug, and whether the warning started soon after.
  • How the truck has been working lately: long highway runs, short local trips or a lot of idling, and any regens that were interrupted.
  • Any recent aftertreatment, sensor or engine work, and whether codes were cleared since.
  • Where the truck is now and whether it can still move under its own power.

Not sure exactly where you are?

Your phone can find the spot and write the text for you.

Your position

Open in Maps

What a pin cannot say

Your text

Uses this phone’s location. Nothing is sent: copy it to paste in a message or read it out when you call.

What we check

Depending on the symptoms, the technician may check:

  • Active and stored fault codes from the engine and aftertreatment modules, with freeze-frame data showing what set the derate
  • DEF level, quality and temperature sensor readings
  • The DEF tank heater, line heaters and their relay and wiring
  • The DEF pump, doser and dosing lines, including crystal build-up at the doser
  • NOx sensors before and after the SCR catalyst
  • The DPF differential pressure sensor and its sensing lines
  • Exhaust temperature sensors and regen history, including soot load and how many regens have failed
  • The EGR valve, EGR cooler and EGR flow readings
  • Upstream causes of heavy soot: boost leaks, injector or turbocharger faults
  • Harnesses and connectors routed near the exhaust for heat damage

Common causes

Possibilities, not a diagnosis of your unit:

  • DEF that is contaminated, diluted, or degraded by heat and age
  • Frozen DEF, or a failed tank or line heater
  • A doser or dosing line blocked with DEF crystals
  • A failed NOx sensor or exhaust temperature sensor
  • A cracked, loose or plugged DPF pressure sensing line
  • Too many short trips or long idling, so regens never finish
  • An engine problem upstream producing excess soot
  • A sticking EGR valve or a leaking EGR cooler
  • Wiring damaged by exhaust heat or road salt

Roadside or shop?

Often done where the unit is

  • Reading codes and freeze-frame data to find what triggered the derate
  • Many sensor replacements, where the sensor can be reached safely
  • Wiring, connectors, fuses and relays in the DEF and sensor circuits
  • DPF pressure sensing lines
  • A parked regeneration, where the truck can be parked safely away from anything that can burn

Often better handled in a shop

  • DPF removal for cleaning or replacement
  • EGR cooler or EGR valve replacement that needs major disassembly
  • DEF tank, pump or SCR catalyst replacement
  • Engine repairs behind a soot or EGR problem

Every fault and every spot is different. Describe it on the call and we will tell you what can be done where the unit is.

How it works

  1. Call, or send your location

    Call the location nearest the unit, or text a map pin with the unit number, then call.

  2. Describe the truck, trailer and problem

    What you see, hear and smell, the warning lights or codes, and whether the unit is loaded.

  3. We assess it with you

    From what you describe, and again when the technician reaches the unit: what is wrong, and whether it can be repaired where it stands.

  4. Repair where the unit is, when it is appropriate

    When the fault and the spot allow it to be done safely and properly.

  5. A shop or further work, when it is needed

    When it cannot be done on site, we tell you why and what the next step is.

Where we work: Winnipeg, Highway 1 and Brandon

A derate on the Trans-Canada Highway (Highway 1) between Brandon, Headingley and Winnipeg can drop a loaded truck far below traffic speed. Take the next exit or a wide, safe shoulder while the truck still has power, then tell us which way you were heading and the closest crossroad, exit or kilometre marker.

Roadside assistance and mobile truck and trailer repair 24/7 along the Trans-Canada Highway (Highway 1) between Winnipeg and Brandon, in both directions: Headingley, St. François Xavier, Elie, Oakville, Portage la Prairie, MacGregor, Austin, Sidney, Carberry and Douglas, and the yards and roads around them.

Questions

Will you delete or bypass the DPF, DEF or EGR?
No. Nexgen does not delete, bypass, disable or tamper with emissions systems, and does not install defeat devices. We find the fault and repair the system so it works as designed.
Why does my truck keep needing a DPF regen?
Usually because soot builds faster than it burns off. Short trips and long idling stop regens finishing; an engine problem such as a boost leak, an injector or the EGR can also make extra soot. A faulty pressure sensor or line can make the filter look full when it is not.
Why does the DEF warning come on in winter?
DEF freezes, so the system relies on heaters to thaw it. A failed tank or line heater, its relay or its wiring often shows up first on a cold morning. The truck may run normally once warm, but the fault usually comes back with the next cold start.
Will clearing the codes get me out of derate?
Rarely for long. The engine module re-runs its checks and derates again if the fault is still there, and clearing codes can erase the data that shows what set it. Find and fix the cause instead.
Is this the same as a general computer diagnostic?
It starts the same way, by reading the codes, but goes further into the aftertreatment system. That means checking DEF quality, heaters, sensors, regen history and EGR flow to find why the system is out of range, not only which code is set.